Kd, pKd and IC50: binding affinity explained

Kd is the equilibrium dissociation constant: the concentration of ligand at which half the target is occupied, so a lower Kd means tighter binding. pKd is its negative base-10 logarithm, which turns a range spanning six orders of magnitude into a linear scale. IC50 is an assay-dependent potency readout and is not interchangeable with either.

11 min readLast updated September 16, 2026Educational — not medical advice

Key points

  • Kd is the ligand concentration at which half the target is occupied; lower means tighter.
  • pKd is −log10(Kd in M): 1 nM is pKd 9, and one unit is a factor of ten.
  • Assay error is roughly multiplicative, so pKd — not nanomolar Kd — is the scale on which to state accuracy.
  • IC50 depends on assay conditions; Cheng and Prusoff showed it does not equal Ki under competitive kinetics.
  • Ranking tolerates systematic error, which is why top-k recovery is the metric that matches the decision being made.
  • Beyond roughly 100 pM, tighter binding tends to buy slower clearance rather than more tumour uptake.

Terms on this page

Affinity (Kd)
How tightly a ligand binds its target; the equilibrium dissociation constant is [A][B]/[AB] at equilibrium, equal to koff/kon, with a lower value meaning tighter binding.
pKd
The negative base-10 logarithm of Kd in molar units: a Kd of 1 nM is pKd 9, and working in logarithms keeps affinity data comparable.
IC50
The concentration of an inhibitor that reduces enzyme activity or agonist response by half; it shifts with assay conditions, so it is not interchangeable with Kd or Ki.
Pearson R
The linear correlation between predicted and measured values; it measures linear agreement, not rank order, and for affinity it is computed on pKd rather than on Kd in nanomolar.
SPR (surface plasmon resonance)
A label-free binding assay in which analyte binding to a sensor surface changes the local refractive index, giving association and dissociation rates and from them Kd.

Questions readers ask

  • Can I convert an IC50 to a Kd?

    Not in general. Under competitive inhibition with known substrate concentration and Km you can convert an IC50 to a Ki with the Cheng–Prusoff relation, and Ki is interpretable as the dissociation constant of the enzyme–inhibitor complex. Without those parameters, or for a cell-based readout, there is no valid conversion — the IC50 contains assay effects that no arithmetic can remove.

  • Is a picomolar binder always better than a nanomolar one?

    For a targeting construct that has to circulate, no. Affinity governs occupancy at a given concentration, but whole-body behaviour is governed by clearance, target expression in healthy tissue and residence time. Very slow dissociation can keep a construct in a normal tissue for longer, which for a radioactive payload increases the absorbed dose there.

  • Why is Pearson R quoted on pKd rather than on Kd?

    Because a correlation computed on Kd in nanomolar is dominated by the weakest ligands in the set — the few large numbers pull the fit. On pKd every ligand contributes comparably, the errors are roughly homoscedastic, and the quantity is proportional to binding free energy. Any affinity correlation quoted without naming the scale should be treated as under-specified.

  • What does "recovers more than 80 % of the true top ligands" mean?

    It is a top-k recovery statement: of the ligands that really are the best in a set, what fraction appears in the predicted top group. Epitorix quotes it for 100 generated ligands, in internal benchmarks, and that fence travels with the figure. It is the metric that matches the decision a chemist makes — what to synthesise next — better than any absolute error.

  • Does a predicted Kd remove the need to measure one?

    No. A prediction orders a list; a measurement establishes a value. Every figure on this site is fenced as retrospective or as an internal benchmark for that reason, and the site states outright that its predictions are hypotheses to test at the bench rather than results.

References

Figures from retrospective analyses and internal benchmarks; a preprint describing the evaluation is forthcoming.